IEEE 802.3af/at/bt PoE Switch Power Budget & Cable Drop Calculator
Total Switch PSE Draw
118.64 W
115W PD + 3.64W I²R loss
Switch Utilization
65.9%
10 active PoE ports
Worst Voltage @ PD
49.84 V
5.38 Ω 2-pair loop
Recommended Tier
≥ 180 W
80% rule (148.3W min)
[OK] PoE switch PSU budget, 80% thermal margin, and IEEE PD minimum voltage verified.
# IEEE 802.3af/at/bt PoE Switch Port Schedule (35m CAT6-23AWG @ 30°C)
PSE Rail Voltage : 52 V DC | 2-Pair Loop: 5.38 Ω | 4-Pair Loop: 2.69 Ω
--------------------------------------------------------------------------------
802.3af Cameras : 6 ports × 6.5W PD -> 39.5W PSE (51.3V @ PD)
802.3at Wi-Fi AP : 2 ports × 18.0W PD -> 37.4W PSE (50.1V @ PD)
802.3at Pi 5 HAT : 2 ports × 20.0W PD -> 41.7W PSE (49.8V @ PD)
--------------------------------------------------------------------------------
Total Active Ports: 10 | PD Load: 115 W | Cable I²R Loss: 3.64 W
Total PSE Draw : 118.64 W | Recommended Switch Tier (80% Rule): >= 180 W
Engineering Rules for Reliable PoE+, Wi-Fi 7 & Camera Switching
Adding up nominal PD wattages from datasheets without cable I²R losses and PSU derating is the #1 reason PoE switches randomly reboot Raspberry Pi 5 nodes or PTZ cameras at night when infrared illuminators engage simultaneously.
Apply the 80% Continuous Rule: Keep steady-state PSE port draw at or below 80% of the switch's rated PoE budget (e.g., max 144 W continuous on a 180 W switch).
Prefer 52V–55V Managed Switches: Higher PSE rail voltage lowers current (I = P / V), cutting cable I²R power loss by ~15%–24% compared to 48V supplies.
Back Up Your Core Switch: Keep PoE cameras, APs, and Pi 5 nodes alive during grid outages by sizing battery VA/Wh in our Homelab Power & UPS Calculator.
Why can a 25.5W PoE+ device draw up to 30W from the switch PSU?
IEEE 802.3at guarantees up to 25.5W delivered at the Powered Device (PD) RJ45 jack, while allowing up to 30.0W at the switch Power Sourcing Equipment (PSE) port to cover up to 4.5W of I²R heat dissipation over 100 meters of twisted-pair copper cable.
Why does IEEE 802.3bt (PoE++) cut cable loop resistance in half?
802.3af and 802.3at transmit DC current over only 2 of the 4 twisted pairs. IEEE 802.3bt Type 3 (60W) and Type 4 (90W) energize all 4 twisted pairs in parallel, halving effective copper loop resistance and keeping voltage above the 42.5V PD floor.
Why should I never use Copper-Clad Aluminum (CCA) patch or riser cable for PoE?
Aluminum has ~55% higher DC resistance than pure annealed copper, violates TIA-568 and UL 444 PoE standards, causes severe undervoltage reboots when camera IR LEDs switch on at dusk, and creates fire/oxidation hazards inside cable bundles.